| Liquid or Gas Service |
Usual Temp. Range |
Pressure |
Suggested Gasket |
| Liquid Sodium Chlorate |
70°
F (ambient) |
to 40 PSI |
6962, PP-340, R3400 |
| Chlorine Dioxide Gas |
140° F to 18° F |
near full Vacuum |
PP-340,
R3400, |
| Chlorine Dioxide Solution, 0 to 14gm/l |
45° F - 55° F |
0 to 60 psi |
PP-340, R3400 |
| Chlorine Dioxide Solution,heated 0 to 14 gm/l |
130°
F + |
>80PSI
|
PT-G
White |
| Caustic Scrubber Liquor,or Water |
Ambient |
50PSI |
6962, PP-340, R3400 |
| Chlorine Dioxide/Air Mixture |
45° to 55° F |
|
PP-340/R3400 to slight Vacuum |
|
Note: The above are guidelines only. Specific details should be discussed with our technical people to verify proper use of a particular product in a specific application. Flange design, and materials of construction, quality of flanges used, available bolt torques, ete., can also affect material choices. |
|||
|
|
|
|||
|
||||
|
|
|